Products ISO 9001: 2015 ce
Cement pipes
PREFABRICATED CEMENT PIPES LENGTH 1M | ||||
---|---|---|---|---|
Α/Α | ΕΣΩΤ. DIAMETER (D) MM | LENGTH (L) | WALL THICKNESS (5) mmL) | WEIGHT Kg/m |
1 | Φ150 | 1,00m | 25 | 45 |
2 | Φ200 | 1,00m | 28 | 52 |
3 | Φ300 | 1,00m | 36 | 90 |
4 | Φ400 | 1,00m | 45 | 140 |
5 | Φ500 | 1,00m | 55 | 190 |
6 | Φ600 | 1,00m | 60 | 280 |
7 | Φ800 | 1,00m | 75 | 480 |
8 | Φ1000 | 1,00m | 90 | 700 |
9 | Φ1200 | 1,00m | 100 | 1100 |
10 | Φ1200* | 1,00m | 150 | 1600 |
11 | Φ1500 | 1,00m | 100 | 1400 |
12 | Φ1500* | 1,00m | 150 | 2000 |
Perforated cement pipes are produced in all diameters.
Perforated cement pipes are produced in all diameters.
Possibility of producing armament
CHARACTERISTICS OF TWO METER CEMENT PIPES WITH BELL, SUPPORT & ELASTIC RING | |||||||||
---|---|---|---|---|---|---|---|---|---|
D
(mm)
| S1 (mm)
| S2 (mm)
| S3 (mm)
| F (mm)
| C (mm)
| A (mm)
| B (mm)
| Kg/m
| m/Φορτίο
|
300 | 50 | 60 | 10 | 240 | 530 | 300 | 12 | 210 | 124 |
400 | 5.2 | 6.2 | 10 | 320 | 630 | 300 | 12 | 295 | 88 |
500 | 60 | 7.8 | 12 | 370 | 770 | 300 | 12 | 400 | 65 |
600 | 6.8 | 8.7 | 13.1 | 440 | 900 | 300 | 12 | 535 | 50 |
800 | 8.4 | 11 | 14.5 | 540 | 1150 | 300 | 105 | 800 | 34 |
1000 | 86 | 115 | 175 | 650 | 1450 | 400 | 105 | 1300 | 20 |
1200 | 110 | 140 | 190 | 750 | 1650 | 400 | 125 | 1600 | 16 |
Technical characteristics of D400-1200 L2m Cement Pipes According to the ELOT standard 1916: 2002
ENDURANCE SERIES 75,100,120,150
- Flat bell type
- Bell connection with rubber ring
- Reinforcing steel B500c
- Concrete quality> 40Mp
- Water repellency <= 5%
- Reinforcement coating> = 25mm
- Water / cement ratio <= 0.45
Product quality control
- Strength of concrete in our factory
- Water absorption in our factory
- Geometric deviations in our factory
- Anti-diameter sadness in our factory
ELASTIC RING INCLUDED
* These cement pipes have no support
Sewer pipes
SEWER PIPES Φ1000 | ||||
---|---|---|---|---|
HEIGHT | ΕΣΩΤ. DIAMETER (D) MM | ΕΞΩΤ. DIAMETER (D) MM | WEIGHT Kg/m | |
500mm | 1000mm | 1200mm | 300 | |
1000mm | 1000mm | 1200mm | 600 | |
Καπάκι διάμετρος 1200mm | 200 |
SEWER PIPES Φ1500 | ||||
---|---|---|---|---|
HEIGHT | ΕΣΩΤ. DIAMETER (D) MM | ΕΞΩΤ. DIAMETER (D) MM | WEIGHT Kg/m | |
500mm | 1500mm | 1700mm | 600 | |
1000mm | 1500mm | 1700mm | 1200 | |
Καπάκι διάμετρος 1700mm | 450 |
SEWER PIPES Φ2000 | ||||
---|---|---|---|---|
HEIGHT | ΕΣΩΤ. DIAMETER (D) MM | ΕΞΩΤ. DIAMETER (D) MM | WEIGHT Kg/m | |
500mm | 2000mm | 2200mm | 800 | |
1000mm | 2000mm | 2200mm | 1600 | |
Καπάκι διάμετρος 2200mm | 800 |
ΚΥΟΥΓΚΙΑ | ||||
---|---|---|---|---|
HEIGHT | ΕΣΩΤ. DIAMETER (D) MM | ΕΞΩΤ. DIAMETER (D) MM | WEIGHT Kg/m | |
330mm | 900mm | 1000mm | 130 | |
Καπάκι διάμετρος 1000mm | 110 |
Φ1500 & Φ2000 Διαθέτουν οπλισμό
Όλα τα καπάκια διαθέτουν οπλισμό
Wells
(A) Coronation with connection of torque and incision of internal diameter Φ1200
(B) Reinforced with tight-fitting ring of inner diameter: Φ1200mm Φ1500mm Φ2000mm
A) Cone: Φ600 / Φ1200, H = 1m
B) Ring: Φ1200, H = 1m, 0.75m, 0.50m, 0.25m
Characteristics of wells according to EN 1917 2002 standard
Minimum Wall Thickness: 150mm
They will be able to receive mobile loads of at least 300KN according to EN 19172002.
They will have a 600mm diameter visit opening
The reinforcement will consist of coils that will form a cage.
Type of concrete C25 / 30
Description of Well Departments
- Prefabricated shaft base with pipe connection openings. The internal flow configuration is done with concrete on site after the installation of the pipes.
- Prefabricated cylindrical shaft body with mounted cast iron steps per 300mm
- Prefabricated roof plate (h = 200mm) with sectional narrowing in Φ600
- Prefabricated shaft neck of internal diameter Φ600 with mounted cast iron steps per 300mm
- Injected crown (B 15) with cast iron cover frame d = 600mm.
Remarks
- The placement of the section 4 depends on the required depth of the shaft.
- The connection of the individual parts must be tight with an elastic ring.
Construction Requirements
CONSTRUCTION SPECIFICATIONS: DIN 4034
EXTERNAL PROTECTION: Asphalt paving
Additional Requirements for Sewage Wells
Cement: Antioxidant (S / R)
Internal protection: Coating of walls with aluminum cement.
Roof coating with polyethylene or
Epoxy paint according to Government Gazette 253 / Β / 94
Type | Thickness | Armor |
---|---|---|
Φ1200 | 180 | Φ8/15 |
Φ1500 | 190 | Φ10/15 |
Φ2000 | 210 | Φ10/12 x 2 |
Οπλισμός πλάκας, διπλή σχάρα, κατα DIN 4034
H3 ≤ 2000mm ή H3 = 300mm σταθερό H1, H2 ≤ 2000mm για Φ1200, Φ1500 H1, H2 ≤ 2500mm για Φ2000
Chimneys
CHIMNEYS | ||||||
---|---|---|---|---|---|---|
Α/Α | INTERIOR | ABROAD | HEIGHT | WEIGHT / pc | Packaging / Pallet | |
Φ21 | 21cm | 34x34cm | 24cm | 10.5kg | 104τεμ. | |
Φ27 | 27cm | 34x34cm | 24cm | 13.5kg | 78τεμ. | |
Φ32 | 32cm | 39x39cm | 24cm | 14.5kg | 54τεμ. |
CHIMNEYS | ||||||
---|---|---|---|---|---|---|
Α/Α | INTERIOR | ABROAD | HEIGHT | WEIGHT / pc | Packaging / Pallet | |
25×25 | 25x25cm | 32x32cm | 24cm | 10kg | 72τεμ. | |
30×30 | 30x30cm | 37x37cm | 24cm | 12.5kg | 54τεμ. | |
40×40 | 40x40cm | 49x49cm | 24cm | 19kg | 28 ή 32τεμ. |
Windproof Concrete Hat | ||||
---|---|---|---|---|
Α/Α | ABROAD | Weight per SET | Packaging / Pallet | Remarks |
Ν20 | 32x32x36cm | 40kg | 24ΣΕΤ | The N20 hat is suitable for use with the chimney Φ21 |
Ν25 | 38x38x42cm | 55kg | 15ΣΕΤ | The N25 cap is suitable for use with chimneys Φ27 and 25 × 25 |
N30 | 45x45x42cm | 70kg | 15ΣΕΤ | The N30 cap is suitable for use with chimneys Φ32 and 30 × 30 |
Chimney visible with brick
410 x 410 x 240 mm Exterior
Φ260 x 240 mm Interior
Weight: 30 kg
Packing: 36 Pieces